Select Publications
Journal articles
2012, 'Optimal stimulus current waveshape for a Hodgkin-Huxley model neuron.', Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Conference, 2012, pp. 4627 - 4630
,2011, 'A continuum model of retinal electrical stimulation', Journal of Neural Engineering, 8, pp. 1 - 13, http://dx.doi.org/10.1088/1741-2560/8/6/066006
,2011, 'A method for control of an implantable rotary blood pump for heart failure patients using noninvasive measurements', Artificial Organs, 35, pp. 174 - 180, http://dx.doi.org/10.1111/j.1525-1594.2011.01268.x
,2011, 'Activation of retinal ganglion cells following epiretinal electrical stimulation with hexagonally arranged bipolar electrodes', Journal of Neural Engineering, 8, pp. 1 - 12, http://dx.doi.org/10.1088/1741-2560/8/3/035004
,2011, 'Electric crosstalk impairs spatial resolution of multi-electrode arrays in retinal implants', Journal of Neural Engineering, 8, pp. Article number: 046016, http://dx.doi.org/10.1088/1741-2560/8/4/046016
,2011, 'Temporo-spatial model construction using the MML and software framework', IEEE Transactions on Biomedical Engineering, 58, pp. 3528 - 3531, http://dx.doi.org/10.1109/TBME.2011.2168955
,2010, 'A computational model of direct brain stimulation by electroconvulsive therapy.', Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Conference, pp. 2069 - 2072
,2010, 'Acousto-optic modulation by pulsed optical excitation: implications to imaging in turbid media', Optics Letters, 35, pp. 2780 - 2782
,2010, 'Anisotropic scattering of discrete particle arrays', Optics Letters, 27, pp. 951 - 959, http://www.opticsinfobase.org/abstract.cfm?uri=josaa-27-5-951
,2010, 'Implications of ultrasound beam shape on the modulation of diffuse light: analysis using spatio-temporal perturbation of the refractive index', Journal of Optics, 39, pp. 126 - 135
,2010, 'Parameter-Optimized Model of Cardiovascular– Rotary Blood Pump Interactions', IEEE Transactions on Biomedical Engineering, 57, pp. 254 - 266
,2006, 'A comparison of 1-D models of cardiac pacemaker heterogeneity', IEEE Transactions on Biomedical Engineering, 53, pp. 164 - 177, http://dx.doi.org/10.1109/TBME.2005.862538
,2005, 'A bidomain model of epiretinal stimulation', IEEE Transactions on Neural Systems and Rehabilitation Engineering, 13, pp. 137 - 146
,2004, 'A gradient model of cardiac pacemaker myocytes', Progress in Biophysics and Molecular Biology, 85, pp. 301 - 323
,2004, 'Parameter estimation in cardiac ionic models', Progress in Biophysics and Molecular Biology, 85, pp. 407 - 431
,2002, 'Shears properties of passive ventricular myocardium', American Journal of Physiology - Heart and Circulatory Physiology, 283, pp. 2650 - 2659
,2001, 'Comment on "Limit Cycle Oscillations in Pacemaker Cells"', IEEE Transactions on Biomedical Engineering, 48, pp. 499 - 520, http://dx.doi.org/10.1109/10.915720
,2001, 'Regional heterogeneity of function in nonischemic dilated cardiomyopathy', Cardiovascular Research, 49, pp. 308 - 318, http://dx.doi.org/10.1016/S0008-6363(00)00248-0
,2001, 'Inhomogeneity of action potential waveshape assists frequency entrainment of cardiac pacemaker cells', IEEE Transactions on Biomedical Engineering, pp. 1108 - 1115
,2001, 'Limit Cycle Oscillations in Pacemaker Cells', IEEE Transactions on Biomedical Engineering, pp. 1134 - 1137
,2001, 'Vagal entrainment of heart rate is simulated by an integrator with feedback', Australasian Physical and Engineering Sciences in Medicine, pp. 86 - 94
,2000, 'A triaxial-measurement shear-test device for soft biological tissues', Journal of Biomechanical Engineering, 122, pp. 471 - 478, http://dx.doi.org/10.1115/1.1289624
,1999, 'Functional heterogeneity and recovery of septal function after successful LV volume reduction in patients with dilated cardiomyopathy', CIRCULATION, 100, pp. 117 - 117, https://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=WOS:000083417100606&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=891bb5ab6ba270e68a29b250adbe88d1
,1999, 'Shear properties of passive ventricular myocardium', FASEB JOURNAL, 13, pp. A1075 - A1075, https://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=WOS:000082132902472&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=891bb5ab6ba270e68a29b250adbe88d1
,1998, 'Review of ionic models of vagal-cardiac pacemaker control', Journal of Theoretical Biology, 192, pp. 265 - 274
,1998, 'Review of ionic models of vagal-cadiac pacemaker control', Journal of Theoretical Biology, 192, pp. 265 - 274
,1997, 'Simulations of postvagal tachycardia at the single cell pacemaker level: a new hypothesis', Annals of Biomedical Engineering, pp. 769 - 782
,1996, 'Ion currents underlying sinoatrial node pacemaker activity: a new single cell mathematical model', Journal of Theoretical Biology, 181, pp. 245 - 272
,1996, 'Ion currents underlying sinoatrial node pacemaker activity: a new single cell mathematical model', Journal of Theoretical Biology, 181, pp. 245 - 272
,1996, 'Vagal control of sinoatrial rhythm: a mathematical model', Journal of Theoretical Biology, 182, pp. 21 - 44
,1996, 'Vagal control of sinoatrial rhythm: a mathematical model', Journal of Theoretical Biology, 182, pp. 21 - 44
,1993, 'Modification of DiFrancesco-Noble equations to simulate the effects of vagal stimulation on in vivo mammalian sinoatrial node electrical activity', Annals of Biomedical Engineering, 21, pp. 321 - 335, http://dx.doi.org/10.1007/BF02368625
,