Journal articles
, 2014, 'Physiological control of dual rotary pumps as a biventricular assist device using a master/slave approach', Artificial Organs, 38, pp. 766 - 774, http://dx.doi.org/10.1111/aor.12303
, 2014, 'In-vitro evaluation of physiological controller response of rotary blood pumps to changes in patient state', Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference, 2014, pp. 294 - 297, http://dx.doi.org/10.1109/EMBC.2014.6943587
, 2014, 'Starling-like flow control of a left ventricular assist device: In vitro validation', Artificial Organs, 38, pp. E46 - E56, http://dx.doi.org/10.1111/aor.12221
, 2014, 'Banding of Right Ventricular Assist Device (RVAD) of Outflow Conduit: Is It Really Necessary With Current Devices?', The Journal of Heart and Lung Transplantation, 33, pp. S238 - S238, http://dx.doi.org/10.1016/j.healun.2014.01.620
, 2013, 'Evaluation of a morphological filter in mean cardiac output determination: Application to left ventricular assist devices', Medical and Biological Engineering and Computing, 51, pp. 891 - 899, http://dx.doi.org/10.1007/s11517-013-1061-6
, 2013, 'Developments in control systems for rotary left ventricular assist devices for heart failure patients: a review', Physiological Measurement, 34, pp. R1 - R27, http://dx.doi.org/10.1088/0967-3334/34/1/r1
, 2013, 'In vitro evaluation of aortic insufficiency with a rotary left ventricular assist device', Artificial Organs, 37, pp. 802 - 809, http://dx.doi.org/10.1111/aor.12143
, 2012, 'Comparison of Preload-Sensitive Pressure and Flow Controller Strategies for a Dual Device Biventricular Support System', Artificial organs, 36, pp. 256 - 265, http://dx.doi.org/10.1111/j.1525-1594.2011.01344.x
, 2012, 'Theoretical Foundations of a Starling‐Like Controller for Rotary Blood Pumps', Artificial Organs, 36, pp. 787 - 796, http://dx.doi.org/10.1111/j.1525-1594.2012.01457.x
, 2011, 'Haemodynamic modeling of the cardiovascular system using mock circulation loops to test cardiovascular devices', Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society EMBS, pp. 4301 - 4304, http://dx.doi.org/10.1109/IEMBS.2011.6091068
, 2011, 'Replication of the Frank-Starling response in a mock circulation loop', Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society EMBS, pp. 6825 - 6828, http://dx.doi.org/10.1109/IEMBS.2011.6091683